ENHANCED EFFICIENCY OF TREATMENT OF TNT WASTEWATER BY INTERNAL ELECTROLYSIS REACTION USE BIMETALIC MATERIALS Fe-Cu

Authors

  • Vu Duy Nhan Institute of Chemistry and Materials, 17 Hoang Sam Street, Cau Giay, Hanoi

DOI:

https://doi.org/10.15625/2525-2518/54/4B/12018

Keywords:

bimetal Fe-Cu, treatment TNT, internal microelectrolysis.

Abstract

 In this article, wastewater containing 2,4,6 trinitrotoluen (TNT) was treated by internal microelectrolysis with bimetal Fe-Cu materials. Components of TNT pollutant content was identified by HPLC method. Examined factors: pH, time, temperature, concentration of Fe-Cu bimetal to efficient treatment of TNT in the wastewater. With conditions at pH 5, bimetal Fe-Cu dosage of 50 g for l litre of wastewater, TNT original content in the wastewater infected about 95-106.4 mg/l, temperature of 25 0C, after 6 hours of processing time, content TNT rest 0.2 - 0.5 mg/l, after 6 hours not observed.

Downloads

Download data is not yet available.

Downloads

Published

2018-03-22

Issue

Section

Articles